Bio-Rad NGC Quest 10 Plus FPLC System

ngc quest10

Features: - For separating biomolecules at high resolution using accurate gradient

- 2X NGC F10 pump modules for a flow rate of 0.001–10 ml/min at 3,650 psi (252 bar, 25.2 MPa)

- 1X Sample pump for application of large volume of sample

- NGC multi-wavelength detector module for simultaneous four-wavelength detection at 190–800 nm, for high-accuracy detection of proteins, peptides, and nucleic acids

- pH and conductivity detectors

- BioFrac fraction collector for up to 180 samples

ChromLab™ Software provides powerful system control, automated methods, and analysis options

Staff-in-charge:

- YK Suen
Back-up Support: - Randy / Venus
Location: LIBSB 512
Booking: - For SBS MEMBERS ONLY.

- Not open to non-SBS users.

- New users please contact Dr. Suen in person for discussion before start

Guidelines and forms: 1. General Guidelines of use of Bio-Rad NGC LC Systems

2. Guidelines on Core Chromatography Column Usage

3. Column Request Form

 

BIO-RAD NGC Discover 10 Pro Liquid Chromatography System

 ngc discover10

Features: - For higher throughput applications with rapid, robust automation and method development

- Method optimization – Optimal purification condition can be determined in an automated systematic manner using Scouting Wizard in ChromLab software

- Multi-step / Tandem Purification – Multi-step purification templates offer optimal efficiency for the tandem purification in multidimensional chromatography strategies or sequential purification of samples in multiple columns

- 2X NGC F10 pump modules for a flow rate of 0.001–10 ml/min at 3,650 psi (252 bar, 25.2 MPa)

- 1X Sample pump for application of large volume of sample

- NGC multi-wavelength detector module for simultaneous four-wavelength detection at 190–800 nm, for high-accuracy detection of proteins, peptides, and nucleic acids

- pH and conductivity detectors

- 1X Buffer blending valve

- ChromLab™ Software provides powerful system control, automated methods, and analysis options

Staff-in-charge:

- YK Suen
Back-up Support: - Randy / Venus
Location: LIBSB 512
Booking: - For SBS MEMBERS ONLY.[Login Booking System]

- Not open to non-SBS users.

- New users please contact Dr. Suen in person for discussion before start

Guidelines and forms: 1. General Guidelines of use of Bio-Rad NGC LC Systems

2. Guidelines on Core Chromatography Column Usage

3. Column Request Form